Access control

Electric strike access control

An electric strike replaces the strike plate in the door frame, so the door keeps its own lock and handle. It's a neat, low-cost way to add fob access to existing doors, from offices to classrooms.

This page shows doors with an electric strike in the frame. Using maglocks instead? See how maglock doors work.

See it in action

Getting in with a fob

An electric strike sits in the door frame where the latch goes. Hold your fob to the reader and, if you're allowed in at that time, the strike releases the latch so you can push the door open. Every entry is recorded.

Fob entry demonstration Outside a building, a person walks up to the door and holds a fob to the reader. The reader light turns green, a signal travels to the door controller above the ceiling, which checks the fob and releases the electric strike. The door opens, the person walks in, and the door closes and locks again. ABOVE THE CEILING Out of sight, on the secure side Door controller Electric strike Locked Released Reader ACCESS GRANTED
Sarah holds her fob to the reader. The controller checks she's allowed in and powers the strike, so its keeper swings free and the door's latch can pass.
Close up

How the strike holds a night latch

Most strike doors keep their own lock, such as a night latch. The strike replaces the plate in the frame that the latch clicks into, and its keeper decides whether the latch can get out. From the inside, turning the night latch knob pulls the latch back, so people can always leave, even in a power cut.

Close-up of an electric strike with a night latch Seen from above. The night latch on the inside of the door has a sprung, sloped latch that sits in the electric strike on the frame. While locked, the strike's keeper stops the latch coming out, so the door can't be pushed open. When a fob is accepted, 12 volts releases the keeper, it swings out of the way and the door opens. When the power goes off the keeper springs back. As the door closes, the sloped face of the latch rides over the keeper, the latch is pushed in, then it springs back out into the strike and the door is locked again. INSIDE (SECURE SIDE) OUTSIDE Looking down from above Door frame Push Door 12V Night latch Electric strike Latch Keeper LOCKED FOB ACCEPTED: RELEASED POWER OFF: KEEPER BACK CLICK: LOCKED AGAIN
Seen from above: the keeper holds the latch until the strike is powered, and the sloped latch clicks back in as the door closes.
  1. LockedThe latch sits in the strike. The keeper stops it coming out, so pushing the door does nothing.
  2. Fob acceptedThe controller sends 12V to the strike and the keeper is free to swing out of the way.
  3. Door opensAs the door is pushed, the latch swings out past the keeper.
  4. Keeper resetsThe power goes off and a spring closes the keeper again.
  5. Door closesThe latch's sloped face rides over the keeper and is pushed in, then springs back out with a click.
Leaving the building

Getting out with the exit button

Nobody needs a fob to leave. One press of the exit button releases the strike. On most strike doors you can also just turn the handle on the inside, because the door's own lock lets you out.

Exit button demonstration Inside the building, a person walks to the door and presses the green exit button. A signal travels to the door controller above the ceiling, which releases the electric strike. The door opens, the person walks out, and the door closes and locks again. ABOVE THE CEILING Out of sight, on the secure side Door controller Electric strike Locked Released EXIT Exit button DOOR RELEASED
A press of the exit button tells the controller to release the strike, and the latch catches again once the door closes.
In an emergency

When the fire alarm goes off

On fire escape routes we fit fail-safe strikes, which need power to stay locked, and wire the fire alarm panel to a fire relay in their power supply. The moment the alarm sounds, the relay cuts the power and the doors release. Fail-secure strikes stay locked when the power goes, so they suit doors where people inside can always get out with the handle.

Fire alarm release demonstration The fail-safe electric strike is powered from a power supply through a fire relay above the ceiling. When the fire alarm goes off, the fire alarm panel signals the relay, the relay opens and cuts the power to the strike, and the door releases. The person walks out to safety. ABOVE THE CEILING Out of sight, on the secure side 12V 0V, power cut Fire relay Power supply Electric strike Locked Released FIRE Fire alarm panel FIRE ALARM: DOORS RELEASED
The fire alarm panel signals the fire relay, which cuts the 12V supply to the fail-safe strike. With no power, the keeper swings free and the door opens.
Key components

What makes up an access controlled door

A strike door has the same building blocks as a maglock door, all wired back to a door controller on the secure side. Only the lock is different.

How an access controlled door is wired The door controller sits in the middle. Wired to it are the reader, the exit button, the door contact, the electric strike, the power supply and the network for the management software. The break glass unit is wired into the lock's power so it can always release the door. Door controller 3 Reader2 1 Fob Exit button5 Door contact7 Electric strike4 Break glass6 Power supply8 Software 9
1

Fob or card

Each person carries their own fob or card. If one is lost, we cancel it in seconds, with no locks to change.

2

Reader

Fitted outside the door. It reads the fob and passes its number to the controller. Keypad and face recognition readers are available too.

3

Door controller

The brain of the door, fitted out of sight on the secure side. It checks whether that fob is allowed through this door at this time, then releases the lock.

4

Electric strike

Fitted in the door frame in place of the normal strike plate. The door keeps its own lock and handle, and the strike lets the latch through when the controller tells it to.

5

Exit button

Lets people out from the inside with one press, so nobody needs a fob to leave.

6

Break glass

On fail-safe strikes, a green emergency release beside the exit cuts the power so the door always opens. Fail-secure doors open from inside with the handle instead.

7

Door contact

A magnetic sensor that tells the system whether the door is open or shut, and warns if it's forced or left open.

8

Power supply

A dedicated power supply with battery backup keeps doors working and secure through short power cuts.

9

Software

Add and remove people, choose which doors and times they can use, and see who went where, from a PC or app.

Planning access control for your site?

Tell us how many doors and people you have, and we'll do the rest. Covering the North East, North West, North Yorkshire and southern Scotland.

Request a free survey